- Alarm parameters only allow now integer values
- Added support for Real Time Alarms: BUSBAR_LINE_NULL_VOLTAGE , BUSBAR_UNDER_VOLTAGE, BUSBAR_OVER_VOLTAGE , FEEDER_LINE_OVERCURRENT ,FEEDER_LINE_NULL_CURRENT
- Added new parameters for each alarm type: BUSBAR_LINE_NULL_VOLTAGE , BUSBAR_UNDER_VOLTAGE, BUSBAR_OVER_VOLTAGE , FEEDER_LINE_OVERCURRENT ,FEEDER_LINE_NULL_CURRENT
- Fuse Blown Alarm created
- Added Wave form Capture Feature
- Status validation period changed to the user
- Device in bulk created - Added new parameters: (name, user, auth type, password, timeserver url and port)
- Device in bulk created - Added option to return device token
- Solve the issue - DeepGrid AI tags request is in infinite loop
- Solve the issue - User was not able to see the Last Data on Dead Section App
- Solve the issue - Resolved alarm e-mail notification sends empty message
- Solve the issue - Users can be deleted without entering the email as confirmation
- Solve the issue - If the user were in a sub-level of Events, Substations and Devices and clicks in the Eneida logo in the header leads to misbehaviour in the navigation
- Solve the issue - The app crashes if we select a "green" substations and click twice in "Heat map"
- Solve the issue - The aggregation interval for the downloads doesn't work, the download is always made with the 30m aggregation
- Changed the way that Status validation period is presented to the user - removed “delay” parameter from “Overvoltage” alarm and changed “delay” parameter label in Undervoltage to “Status validation period (seconds) (shared with Overvoltage”)
- Solve the issue: After create the SDS and the feeders if the user goes back and forward to add another feeder the SDS is not updated
- Solve the issue: In the SDS creation, after the feeders, if the user continues the app, leads to a new screen (BLEConnectingController) that blocks the app
- 1 mn for agregation and communication
- Increment HW revision - SN 88 and 95
- Support for DTVIG-PMT2
- Increment HW revision - SN 94
- Increment HW revision - SN 88 and 95
- Support for DTVIG-PMT2
- Increment HW revision - SN 94
- Support do DTVIg V6 units on Web App and API
- Fix Bug - Fuse Way must not allow negative values (Web App and API side)
- Missing Invalid email information on login form
- Clear alarms from devices decommisioned
- Support for 1 min for aggregation and communication on Deepgrid
- Support to DTVIg hardware V6 units
- 1 min for aggregation and communication on Deepgrid
- Graphics from voltage are now disagregated/separated (distinguish between feeder and busbar)
- Device detection alarms
- Fixed issue when SDS doesn't have GPS coordinates (nullable values)
- New Help forms.
- DTVI4-g PMT2 support added.
- Other small bugs fixed.
- DTVI4-g PMT2 support added.
- New Push Notification system when there is a new version available.
- Other small bugs fixed.
- Improve visualization of events in Dashboard map.
- List child substations on PDS summary.
- Add device firmware update deploy date.
- Pole Mount bug related with Voltage Alarms fixed.
- Bug while changing DTVI acquisition parameters fixed.
- Other small bugs fixed.