- Dashboard page migration.
- General Configuration page migration.
- Regions page migration.
- Help and About migrations.
- Energy Historical Graph bug fixed.
- User page refinement.
- Download large files improvement.
- Reports and Exports now have file size detail.
- Some missing metrics added.
- Show Firmware information on the Device Page.
- Reports and Exports have a new navigation system.
- Bug fixed on Capacity Optimization app: Sometimes was showing the wrong plot.
- Other small bugs fixed.
- Fixed input 1 required to be active for all voltage related parameters acquisition.
- Fixed a locking condition that could result in MEA stopping to work.
- Fixed a condition that required all inputs to be active for calculations derived from waveform (Flicker, THD, HD).
- Fixed state machine de-synchronization between the two micros (COM and MEA).
- Fixed a communication issue between both micros that resulted in some missing data for NPQ vHD.
- Fixed iTHD calculation for current harmonics - introduced in MEA version 13.
- Removed external 32 kHz forced validation.
- Fixed Umax and Uss calculations for NPQ RVC.
- Some other minor bugs fixed and improvements.
- Fixed endless loop if NTP execution fails.
- Updated SD-card driver.
- Fixed state machine de-synchronization between the two micros (COM and MEA).
- Fixed a communication issue between both micros that resulted in some missing data for NPQ vHD.
- Set default NTP server to "time.google.com" - if device commissioned with previous default "3.pt.pool.ntp.org" it will automatically change to the new one.
- Fixed events data sending before time synchronization occurs.
- Fixed wrong variable being sent as Pmax - introduced in COM_014.
- Removed external 32 kHz forced validation.
- Improved the method to return to factory mode (clear all commissioning information). Useful in case issues with unique APN credentials arise.
- Some other minor bugs fixed and improvements.
- DTVI-m improvements - added more data available in Modbus RTU.
- Fixed a device reset when powering modem.
- Initial DTVI-m version.
- Add support to process modem SIM7600 unsolicited codes.
- Fixed SIM7600 version check - a specific version is required for MQTT 3.1.1.
- Added MQTT NDEATH messages.
- Fixed MQTT state machine to be non blocking which could result in no data being acquired if device is stuck in MQTT process.
- Fixed HD and THD calculations - values too stable over time.
- Some other minor bugs fixed and improvements.
- Fixed HD and THD calculations - values too stable over time.
- Improved Flicker calculation accuracy.
- Improved accuracy for current HD/THD calculations for Micro~flex coils.
- Improved Earthing Chart interface.
- Addition of a context menu in the alarm table that allows the user to center the map in a substation.
- Edit mqtt interface url.
- Addition of a search field to help the user to select a substation when creating a report or export.
- Improved user details page.
- Show property file size in exports/reports details.
- Global States SVG bug while using Mozilla Firefox fixed
- Bug fix that did not show the alarm tooltips.
- Add phase indication to substation global states, of feeder level.
- Improve interface of create substation page.
- Edit communication settings for a single device.
- Added support for MQTT process to reset SIM7600.
- Fixed daily reset (only DTVI-g) not happening sometimes.
- Improved the commissioning/de-commissioning process.
- Fixed a reset which occurred 5 seconds after power-up.
- Improved APN settings and Timeserver flexibility.
- Added the possibility for 4G (SIM7600) devices to communicate through HTTP or HTTP and MQTT.
- Added support for MQTT 3.1.1.
- Fixed comms rate being used for data aggregation instead of acquisition rate.
- Aggregation (Normal mode and Use Cases) only starts after synchronizing with desired period (implies valid clock).
- Some other minor bugs fixed and improvements.